Because the fluid heating system is
powered by electricity, and has an electronic control system, it is
necessary to have a battery powered volt/ohm multi-meter and a clamp-on amp
meter for troubleshooting. For instance, if a diagnostic code appears for a
bad element, it will be necessary to use an ohm meter to determine which
element is bad. See Required Test Equipment & Techniques for Measurements
below for additional details on the tools necessary for testing and
servicing the heater.
Voltage measurements are taken, with the power
turned on to the heater, at the control board lugs, to verify that all
wiring is correct and that there is power to all the incoming circuits.
The multi-meter should be dialed to AC volts, on the appropriate scale to
enable a measurement reading up to 260 volts AC. The voltage across the
incoming power lugs on the board must always be measured by placing each
of the two multi-meter probes on the control board lugs labeled L1 & L2
for each circuit. (Never measure from one lug to ground in an attempt to
verify proper voltage at the circuit). The voltage across the lugs should
be between 200 and 250 volts AC. If voltage at any pair of lugs (L1 & L2)
is zero, either the power wire legs are out-of-phase or the circuit
breaker is turned off or even mislabeled (serving some other device in the
home or building). |
|
|||||||||||||||
Home | Question & Answer |
Contact / Comments | Ask the Experts|
Links | Sitemap
Order Online | Return Policy
| Troubleshooting |
Warranty Info | View Cart
Gas vs. Electric Water Heaters |
Product Guide |
Heater Applications
Electrical Guide & Requirements |
Plumbing & Electric Installation
| Cost Comparisons |
Repair & Removal
1-877-482-6553