INTERNAL WORKINGS & IDENTIFICATION
TWO CHAMBER (RA-9, 11, 14)
<< back to the
Product Guide

1:Heating Element #1 2:Heating
Element #2 3:Inlet Water Tube
4:Level Detect Screw 5:Outlet Water Tube
6:Printed Circuit Board
7:Heating Element Relays (4) 8:Transformer
9:Audible Speaker
10:Output Temperature Control 11:Microprocessor
Control Chip 12:Blue Button; Activates Audible
13:Terminal Spades for Leak Detect Wires 14:Triacs
(4) 15:Triac Mounting Blocks to Heat Sink (4)
16:Copper Heat Sink Tube
L1:Power Connection Lugs (208 — 240 VAC)
L2:Power Connection Lugs (208 — 240 VAC)
H. Limit:High Temperature Limit Switches
TH-IN:Inlet Temperature Sensor
TH-1:Chamber Temperature Sensor #1
TH-2:Chamber Temperature Sensor #2
back to top |
|