INTERNAL WORKINGS & IDENTIFICATION
FOUR CHAMBER (RA-18, 22, 28)
<< back to the
Product Guide

1:Heating Element #1 2:Heating
Element #2 3:Heating Element #3
4:Heating Element #4 5:Inlet Water Tube
6:Level Detect Screw
7:Level Detect Screw 8:Outlet Water Tube
9:Printed Circuit Board
10:Transformer 11:Heating Element Relays (8)
12:Audible Speaker
13:Output Temperature Control 14:Microprocessor
Control Chip
15:Blue Button; Activates Audible 16:Terminal
Spades for Leak Detect Wires
17:Triacs (4) 18:Triac Mounting Blocks to Heat
Sink (4) 19:Copper Heat Sink Tube
L1:Power Connection Lugs (208 — 240 VAC)
L2:Power Connection Lugs (208 — 240 VAC)
H. Limit:High Temperature Limit Switches (2)
TH-IN:Inlet Temperature Sensor
TH-1:Chamber Temperature Sensor #1
TH-2:Chamber Temperature Sensor #2
TH-3:Chamber Temperature Sensor #3
TH-4:Chamber Temperature Sensor #4
back to top |
|