<< back to the Plumbing & Electric Installation Guide
WARNING: Tankless Water
Heater Installation and service must be by qualified personnel only!
MODELS RA-14 THROUGH RA-28 REQUIRE MULTIPLE
POWER SOURCES. WHEN WIRED DIRECTLY TO THE BREAKER BOX, THEY REQUIRE MORE
THAN ONE DOUBLE POLE CIRCUIT BREAKER.
HEATER SUPPLY SIDE
CONNECTION MAIN POWER CIRCUIT BREAKER DIAGRAM
Where required by code, use a disconnect switch
adjacent to the heater. When making this type of Tankless Water Heater
installation, BE SURE THE MAIN FEEDER WIRES USED ARE PROPERLY SIZED.
1. After all electrical connections have been made, every effort should be made to verify a safe Tankless Water Heater Installation. Again check to be sure all connections in the unit disconnect and/or circuit breaker panel are secure. Check to be sure that an adequate ground has been properly connected. Check to be sure that adequate size breakers have been installed properly. Remember that breakers that are too large are more dangerous than breakers that are too small.
2. RUN WATER THROUGH THE UNIT UNTIL AIR IS PURGED.
Check only after the Pre-Power Check has been completed and the unit filled with water. Turn on the Main Power Circuit Breakers. Verify that the heater’s GREEN POWER-ON indicator light is illuminated. USE EXTREME CAUTION WHEN CHECKING VOLTAGE TO THE UNIT.
Check the voltage available to each active power circuit. Models RA-9 to
RA-28 are designed to operate from a 208V to 240V power supply. Connect a
voltmeter at power circuit 1 (CKT 1) between L1 and L2. (For models with
multiple power circuits utilized, continue to check voltage at each
additional power circuit.)
Turn water on MEDIUM-LOW utilizing any sink
allowing water to run for a couple of minutes to ensure that all air is
purged from the unit. You will hear a "click" as the relays on the circuit
board engage. It is normal to hear a "hissing" or "crackling" noise from the
heat exchanger after the unit is started. With the unit's cover removed,
verify with an ammeter that there is ELECTRICAL CURRENT through each heating
element circuit. DISREGARD THE WATER TEMPERATURE WHILE DOING THIS TEST. Thermostat settings are factory preset for units employing a circuit board potentiometer (thermostat). THIS Tankless Water Heater Installation MUST BE DONE BY QUALIFIED AND LICENSED CONTRACTORS. Refer to your local electrical and plumbing codes for additional information.
|
|
|||||||||||||||||||
Home | Question & Answer |
Contact / Comments | Ask the Experts|
Links | Sitemap
Order Online | Return Policy
| Troubleshooting |
Warranty Info | View Cart
Gas vs. Electric Water Heaters |
Product Guide |
Heater Applications
Electrical Guide & Requirements |
Plumbing & Electric Installation
| Cost Comparisons |
Repair & Removal
1-877-482-6553